바로가기
메인메뉴로 바로가기
콘텐츠 바로가기
하단메뉴로 바로가기
패밀리사이트 바로가기


진료과

  • 암병원(강남)-대장암센터, 전립선암센터, 간암센터, 자궁·난소암센터, 위·식도암센터

전문진료분야

  • <영상의학과> 복부 비뇨생식계 영상의학. 의학물리학. 방사선 피폭 저감화

교육 및 임상 경력

  • 2002.3-2003.2    원주기독병원  인턴
  • 2003.3-2007.2    강남세브란스병원  전공의
  • 2010.5-2012.2    강남세브란스병원  강사
  • 2012.3-  현재      강남세브란스병원  임상조교수

학력사항

  • 2002. 2 원주의과대학졸업 (학사)
  • 2005. 2 원주의과대학원 졸업 (석사)

논문

  • Early biliary complications of laparoscopic cholecystectomy: Evaluation on T2-weighted MR cholangiography in conjunction with mangafodipir trisodium-enhanced 3D T1-weighted MR cholangiography
    AMERICAN JOURNAL OF ROENTGENOLOGY 183/6 :1559-1566,2004
  • Focal Eosinophilic Necrosis on Superparamagnetic Iron Oxide-Enhanced MRI
    AMERICAN JOURNAL OF ROENTGENOLOGY 194/ :1296-1302,2010
  • Alpha-fetoprotein 상승을 동반한 위암의 음낭 내 전이: 증례 보고
    대한영상의학회지 63/5 :471-474,2010
  • Segmental Adenomyomatosis of Gallbladder: CT Assessment of the Patterns of Cholecystolithiasis
    대한영상의학회지 64/3 :253-259,2011
  • Detection of small intrahepatic metastases of hepatocellular carcinomas using diffusion-weighted imaging: Comparison with conventional dynamic MRI
    Magnetic Resonance Imaging 29/7 :985-992,2011
  • 바터팽대부암종(Ampullary Carcinoma)의 진단에 있어서 18F 2-Fluoro-2-Deoxy-D-Glucose Positron Emission Tomography Scan의 유용성
    대한영상의학회지 65/2 :161-166,2011
  • Cerebral Computed Tomography Angiography Using a Low Tube Voltage (80 kVp) and a Moderate Concentration of Iodine Contrast Material - A Quantitative and Qualitative Comparison With Conventional Computed Tomography Angiography
    INVESTIGATIVE RADIOLOGY 47/2 :142-147,2012
  • Diffusion-weighted imaging versus superparamagnetic iron oxide (SPIO)-enhanced MRI: exclusive and combined values in the assessment of hepatic metastases
    Magnetic Resonance Imaging 30/ :554-561,2012
  • CT Angiography of the Renal Arteries: Comparison of Lower-Tube-Voltage CTA With Moderate-Concentration Iodinated Contrast Material and Conventional CTA
    AMERICAN JOURNAL OF ROENTGENOLOGY 199/1 :96-102,2012
  • Computed tomographic venography for varicose veins of the lower extremities: Prospective comparison of 80-kVp and conventional 120-kVp protocols
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY 36/5 :583-590,2012
  • Iatrogenic Injury in the Lateral Segment of the Liver after Pancreatoduodenectomy: Early Follow-Up CT Features and Clinical Implications
    대한영상의학회지 66/5 :451-457,2012
  • 성인에서 천미부 기형종의 선암으로 전환 1예
    대한내과학회지 85/1 :101-105,2013
  • CT Venography for Deep Vein Thrombosis Using a Low Tube Voltage (100 kVp) Setting Could Increase Venous Enhancement and Reduce the Amount of Administered Iodine
    KOREAN JOURNAL OF RADIOLOGY 14/2 :183-193,2013
  • Preoperative Evaluation of Lymphovascular Invasion Using High-Resolution Pelvic Magnetic Resonance in Patients With Rectal Cancer: A 2-Year Follow-up Study
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY 37/4 :583-588,2013
  • 병리학적으로 림프절 전이가 없었던 조기위암 환자의 위주변 림프절에 대한 수술 전 다중검출기 CT 소견
    대한영상의학회지 69/5 :391-398,2013
  • Evaluation of Lateral Pelvic Nodes in Patients With Advanced Rectal Cancer
    AMERICAN JOURNAL OF ROENTGENOLOGY 202/6 :1245-1255,2014
  • Comparison of Abdominal Ultrasonographic Findings With Endoscopic Ultrasonographic Findings of Solid Pseudopapillary Neoplasms of the Pancreas
    ULTRASOUND QUARTERLY 30/3 :173-178,2014
  • Usefulness of a lead shielding device for reducing the radiation dose to tissues outside the primary beams during CT
    RADIOLOGIA MEDICA 119/12 :951-957,2014
  • Feasibility of 5-Minute Delayed Transition Phase Imaging With 30 degrees Flip Angle in Gadoxetic Acid-Enhanced 3D Gradient-Echo MRI of Liver, Compared With 20-Minute Delayed Hepatocyte Phase MRI With Standard 10 degrees Flip Angle
    AMERICAN JOURNAL OF ROENTGENOLOGY 204/1 :69-75,2015
  • Prognostic Value of the Thickening of the Gallbladder Wall in Acute Hepatitis A
    ULTRASONOGRAPHY 34/2 :139-143,2015
  • MRI Features of Hepatocellular Carcinoma Related to Biologic Behavior
    KOREAN JOURNAL OF RADIOLOGY 16/3 :449-464,2015
  • Cerebral computed tomography angiography using a 70 kVp protocol: improved vascular enhancement with a reduced volume of contrast medium and radiation dose
    EUROPEAN RADIOLOGY 25/5 :1421-1430,2015
  • Validation of 10-Minute Delayed Hepatocyte Phase Imaging with 30° Flip Angle in Gadoxetic Acid-Enhanced MRI for the Detection of Liver Metastasis
    PLOS ONE 10/10 :e0139863-,2015
  • Diffusion-Weighted MRI of Malignant versus Benign Portal Vein Thrombosis
    KOREAN JOURNAL OF RADIOLOGY 17/4 :533-540,2016
  • Feasibility of 10-Minute Delayed Hepatocyte Phase Imaging Using a 30° Flip Angle in Gd-EOB-DTPA-Enhanced Liver MRI for the Detection of Hepatocellular Carcinoma in Patients with Chronic Hepatitis or Cirrhosis.
    PLOS ONE 11/12 :e0167,701-,2016
  • High-flow haemangiomas versus hypervascular hepatocellular carcinoma showing "pseudo-washout" on gadoxetic acid-enhanced hepatic MRI: value of diffusion-weighted imaging in the differential diagnosis of small lesions.
    CLINICAL RADIOLOGY 72/3 :247-254,2017
  • Prediction of pancreatic fistula after pancreatoduodenectomy by preoperative dynamic CT and fecal elastase-1 levels
    PLOS ONE 12/5 :e0177052-,2017
  • Factors affecting survival after concurrent chemoradiation therapy for advanced hepatocellular carcinoma: a retrospective study
    RADIATION ONCOLOGY 12/133 :1-8,2017
  • High prevalence of intracranial aneurysms in patients with aortic dissection or aneurysm: feasibility of extended aorta CT angiography with involvement of intracranial arteries.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY 9/10 :1,017-1,021,2017
  • Multidetector CT findings of histopathologically proven peritoneal tuberculous cold abscesses
    RADIOLOGIA MEDICA 122/4 :248-256,2017
  • Optimization of Split-Bolus CT Urography: Effect of Differences in Allocation of Contrast Medium and Prolongation of Imaging Delay
    AMERICAN JOURNAL OF ROENTGENOLOGY 209/1 :W10-W17,2017
  • Apparent diffusion coefficient of hepatocellular carcinoma on diffusion-weighted imaging: histopathologic tumor grade versus arterial vascularity during dynamic magnetic resonance imaging
    PLOS ONE 13/5 :197,070-197,082,2018
  • Hepatic cavernous hemangiomas: long-term (>5 years) follow-up changes on contrast-enhanced dynamic computed tomography or magnetic resonance imaging and determinant factors of the size change
    RADIOLOGIA MEDICA 123/5 :323-330,2018
  • Tertiary Referral Hospital Experiences of Men Presenting With Painless Postcoital Gross Hematuria and a Suggestion for the Management Algorithm.
    UROLOGY 115/5 :112-118,2018
  • Serous Cystic Neoplasms of the Pancreas: Endoscopic Ultrasonographic Versus Computed Tomography and Magnetic Resonance Imaging Features of Surgically Removed Masses
    ULTRASOUND QUARTERLY 34/3 :122-127,2018
  • Pseudoglandular Formation in Hepatocellular Carcinoma Determines Apparent Diffusion Coefficient in Diffusion-Weighted MRI
    Investigative Magnetic Resonance Imaging 22/2 :79-85,2018
  • Attenuation- Based Automatic Tube Potential Selection in Cerebral Computed Tomography Angiography: Effects on Radiation Exposure and Image Quality
    대한영상의학회지 78/1 :35-43,2018
  • Accuracy of pelvic MRI in measuring tumor height in rectal cancer patients with or without preoperative chemoradiotherapy
    EJSO 45/3 :324-330,2019
  • Peri-ampullary duodenal diverticulum: effect on extrahepatic bile duct dilatation after cholecystectomy
    CLINICAL RADIOLOGY 74/9 :735.e15-735.e22,2019

조은석

콘텐츠 처음으로 이동

네크워크 링크안내/사이트 정보